Suggested Remedy for comment #183 and 184 Changes from the original Draft0.9 text are marked with RED color. Deletions are marked with Strikethrough. Notes to the group or to the Editor are Italic Make the following changes at the subclasses below: 1. Table 33-12 Item 1 Change Item 1 to be: Item Parameter Symbol Unit Min Max Applicable Additional PD Type Information 1 Input Voltage during 36 57 1 overload per item 4 1a Input Voltage during 37 57 1 normal load per item 5 Vport Vdc 1b Input Voltage during PD 39.713 57 2 See 33.3.5.1 overload per item 4 1c Input Voltage during PSE 36 57 2 voltage transient per Table 33-5 item 2a 1d Input Voltage during 41 57 2 normal load per item 5 2. Table 33-12 item 4: Change symbol from "Iport" to "Iport_peak" 3. Table 33-12 item 4: Replace TBD for Type 2 PD with "0.823" (Scan all "0.82" and replace with "0.823" (=0.4/0.35) or leave "0.82" and change ration to 1.139 instead of 1.143 for Class 4 only) (See below that 33.3.5.4 was updated to reflect the dependence of Ipeak with Pclass and Vport.) Vport Ad hoc: Suggested Remedy for comments #183 and 184. Yair Darshan, Microsemi Corporation. Page 1 of 5 4. Make the following changes in 33.3.5.4 Peak operating current. "At any operating condition the peak current shall not exceed PPort max/VPort Iport_peak as defined by Table 33-12 item 4 for more than 50ms max and 5% duty cycle max. ...
-